Arlon 25N and 25FR are woven fiberglass reinforced, ceramic-filled composite materials engineered for use in microwave and RF multilayer printed circuit boards. Combining a non-polar thermoset resin system with a controlled-expansion ceramic filler, 25N and 25FR offer low dielectric constant and loss combined with a low Thermal Coefficient of Dielectric Constant (TCEr) for signal stability over a wide ambient temperature range. Designed for use in multilayer packages, 25N and 25FR offer prepregs that are identical in chemical composition and physical properties with their copper clad laminates for a completely homogeneous finished package for optimal signal integrity.
       
The low dielectric constant (Er) and loss properties, low thermal coefficient of dielectric constant (TCEr), and excellent physical stability characteristics offered by 25N and 25FR materials make them ideal for wireless and digital applications, such as cellular telephones, down converters, low noise amplifiers, antennas and other advanced des ign circuits.
       
Processing for 25N and 25FR materials is consistent with processing for standard high temperature thermoset based printed circuit board substrates.
       
       
General  
Filler / Reinforcement  Ceramic Fiber Glass Fiber  
Features  Fast Molding Cycle Good Dimensional Stability  
Uses  Electrical/Electronic Applications
UL File Number  E80166
Forms  Pellets

Physical Nominal Value Unit Test Method
Specific Gravity 2 1.80 g/cm³ ASTM D792A
Water Absorption 3 (23°C, 24 hr) 0.090 % Internal Method
Volatile Matter 4 0.0 %  
Mechanical Nominal Value Unit Test Method
Flexural Strength (23°C) 241 MPa ASTM D790A
Films Nominal Value Unit Test Method
Tensile Strength - MD  2 (Yield) 96.5 MPa ASTM D882A
Peel Strength 5 875.6 N/m Internal Method
Thermal Nominal Value Unit Test Method
CLTE - Flow      Internal Method
-- 6 1.6E-5 cm/cm/°C  
-- 7 1.8E-5 cm/cm/°C  
-- 8 5.9E-5 cm/cm/°C  
-10 to 140°C 9 5.0E-5 cm/cm/°C  
Thermal Conductivity (100°C) 0.45 W/m/K ASTM E1225
Electrical Nominal Value Unit Test Method
Surface Resistivity (0.305 mm) 8.9E+8 ohms Internal Method
Volume Resistivity (0.305 mm) 4.2E+8 ohms·cm Internal Method
Dielectric Constant 10 (23°C, 10.0 GHz) 3.58   Internal Method
Dissipation Factor 10 (10.0 GHz) 3.5E-3   Internal Method
Flammability Nominal Value Unit Test Method
Flame Rating 11 V-0   UL 94
Additional Information Nominal Value Unit  
Total Mass Loss 12 (125°C) > 0.24 %  
Water Vapor - Recovered  0.070 %  
       
223°C      
3E1/105 + D24/23      
4Maximum 0.10%      
5After Thermal Stress      
6X-axis      
7Y-axis      
8Z-axis      
9Adapted      
10C23/50      
11C48/23/50, E24/125,      
12< 10e-6 torr, Maximum 1.00%      